2022 High quality Dry Block Temperature Calibrator - PR611A/ PR613A Multifunctional Dry Block Calibrator – Panran

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We're committed to furnishing easy,time-saving and money-saving one-stop purchasing support of consumer for Multi-Channel Reference Thermometer, Field Metrology Well, Low Pressure Pneumatic Test Pump, We welcome new and aged buyers from all walks of lifetime to make contact with us for potential small business associations and mutual success!
2022 High quality Dry Block Temperature Calibrator - PR611A/ PR613A Multifunctional Dry Block Calibrator – Panran Detail:

2ee1328188851e307af55c02b5971e2.png

Keywords

l Intelligent dual-zone temperature control

l Editable task mode

l Rapid heating and cooling

l Electrical measurement function

 

1. Overview

PR611A/PR613A dry block calibrator is a new generation of portable temperature calibration equipment that integrates advanced technologies such as intelligent dual-zone temperature control, automatic temperature calibration, and precision measurement. It has excellent static and dynamic temperature control characteristics, built-in independent full-function temperature measurement channel and standard measurement channel, and can edit complex calibration tasks. The automatic calibration of thermocouples, thermal resistances, temperature switches, and electrical signal output temperature transmitters can be realized without other peripherals, It’s very suitable for industrial field and laboratory use.

1.1 Appearance

72c5593bab2f28678457d59d4dfd399.png

NO. Name NO. Name
1 Working cavity 6 Power switch
2 Test terminal area 7 USB port
3 External reference 8 Communication port
4 Minithermocouple socket 9 Display screen
5 External power interface

1.2 Technical characteristics

l It adopts dual zone temperature control technology. The bottom and top of the dry block calibrator heating cavity have two independent temperature control, heating and cooling components. The temperature coupling control algorithm is used to avoid the mutual influence between multiple heating zones during the temperature balance process. . The dual-zone temperature controltechnology is the key to ensure that the effective temperature zone remains stable in a complex and changing environment and to improve the axial temperature uniformity.

l Rapid heating and cooling, by matching the heating and cooling capacity of the current working conditions in real time, while optimizing the control characteristics, the heating and cooling speed can be greatly increased.

l Full-featured electrical measurement channel, the full-featured electrical measurement channel is used to measure various types of thermal resistance, thermocouple, temperature transmitter and temperature switch, with a measurement accuracy better than 0.02%. In addition, for better calibration of thermocouple sensors, a dedicated thermocouple compensation socket with a compensation error better than 0.2°C is integrated on the front panel. l For the reference temperature sensor, in order to facilitate the comparison between the standard device and the temperature element to be calibrated, the standard wire-wound platinum resistance is used as the reference sensor, and it supports multi-point interpolation correction algorithm to obtain better temperature traceability accuracy.

l Editable task mode, can edit and design complex task functions including temperature calibration points, stability criterion, sampling method, delay time and other multiple calibration parameters, so as to realize the automatic calibration process of multiple temperature calibration points.

l Fully automatic temperature switch calibration, with a settable slope temperature rise and fall and switch value measurement functions, can perform fully automatic temperature switch calibration tasks through simple parameter settings.

l Supports USB storage devices. The calibration data generated after the calibration task is executed will be saved in the internal memory in the format of a CSV file. The data can be viewed on the dry block calibrator or exported to a USB storage device through the USB interface.

1.3 List of main functions

 

Software function Hardware function
nOptional internal/external reference sensor to control temperature

nProgrammable thermocouple, thermal resistance multi-point automatic calibration

nAutomatic calibration of slope temperature rising and falling switch value can be set

nInternal storage of calibration data

nMulti-point internal/external reference temperature control parameter self-tuning

nAdaptive temperature control parameters

nReal-time temperature and power curve display

nSelf-defined temperature fluctuation calculation

nU disk storage

nSelf-defined the upper and lower limit of alarm temperature

nOptional ℃, ℉, K

nmV/mA/V/Ω measurement

nSwitching value measurement

nThermocouple measurement function

nTwo-wire, three-wire, and four-wire thermal resistance measurement

nBuilt-in reference compensation

nDC24V output (80mA max)

 

 

2. Technical Parameters

 

2.1 General parameters

ItemModel PR611A PR613A
External dimensions 360mm(H)*150mm(W)*350mm(D) 360mm(H)*180mm(W)*270mm(D)
Product weight 12kg 9.2kg
Rated power 700W 1200W
Working environment range of working temperature: (0~50), Non-condensing range of working temperature: (0~50), Non-condensing
Display screen 4.0 inch industrial touch screen,

Resolution 800×480 pixels

4.0 inch industrial touch screen,

Resolution 800×480 pixels

Power requirements 220VAC±10%,50Hz 220VAC±10%,50Hz
Communication method RS485, (Optional WiFi, Bluetooth)
Calibration period 1year

2.2Temperature field parameters

 

ItemModel PR611A PR613A Remark
Temperature control range -30℃~155 RT+10℃~700℃
Resolution 0.001℃ 0.001℃
Temperature block diameter/insertion depth φ26mm/160mm φ26mm/155mm
Built-in reference

Temperature control accuracy

±0.15℃@0℃

±0.30℃@100℃

±0.15℃@100℃

±0.60℃@600℃

[Note 1]
External reference

Temperature control accuracy

±0.06℃@0℃,100℃ ±0.10℃@100℃

±0.20℃@600℃

[Note 1]
Temperature fluctuation ±0.01℃@0℃,100℃ ±0.02℃@100℃

±0.07℃@600℃

10 minutes
Temperature difference between holes 0.01℃@0℃,100℃ 0.03℃@100℃

0.10℃@600℃

[Note 1]
40mmAxial temperature difference 0.20℃@0℃,100℃ 0.20℃@100℃

0.70℃@600℃

[Note 1][Note 2]
60mmAxial temperature difference 0.50℃@0℃,100℃ 0.50℃@100℃

1.00℃@600℃

[Note 1][Note 2]
Load impact 0.01 0.05℃@100℃

0.20℃@600℃

Use built-in reference [Note 3]
Heating time 23℃~15517min 23℃~700℃ 25min Subject to the temperature at the bottom of thermostatic block
Cooling time 23-30℃ 12min 70010035min
Stabilization time ≤5min ≤10min Use built-in reference
The above technical parameters are all measured at an ambient temperature of 23℃, and the test data is based on the test dedicated thermostatic block PR6115T (aluminum alloy material).

Note 1:Use 2 φ3mm metal rod platinum resistance test;

Note 2:40mm/60mm from the bottom of the socket of the thermostatic block;

Note 3:The test condition is to insert two φ7mm metal rod platinum resistors;

2.3Electrical measurement parameters

 

Type Range Measuring range Accuracy Resolution Remark
Voltage measurement 15mV 0mV~15mV ±0.015%RD+2uV 0.1μV Input impedance≥50MΩ
50mV 0mV~50mV ±0.015%RD+5uV 0.1μV Input impedance≥50MΩ
50V -0V~50V ±0.015%RD+0.005%FS 0.1mV Input impedance≥1MΩ
Resistance measurement 500Ω 0Ω~500Ω ±0.015%RD+0.005%FS 1mΩ Four-wire, output 1mA current
5KΩ 0KΩ~5KΩ ±0.015%RD+0.005%FS 10mΩ Four-wire, output 0.1mA current
Current measurement 50mA 0mA~50mA ±0.015%RD+0.005%FS 1μA Internal resistance=10Ω
Temperature coefficient 2PPM/℃@(Ω、KΩ) 5PPM/℃@(mV、V) 5PPM/℃@(mA)
Note: Wiring is done through the front panel terminals.

2.4Thermocouple temperature measurement parameters

Type Measuring range Accuracy Resolution Remark
S、R 100℃~1768℃ ±0.8℃@600℃

±1.0℃@1000℃

0.01℃ Including reference terminal compensation error
N、K -80℃~1300℃ ±0.6℃@(≤600℃)

±0.1%RD@(>600℃)

WRE325、WRE526 -80℃~2300℃
B 250℃~1820℃
T -200℃~400℃
E -90℃~800℃
J -100℃~1090℃
EA2 -30℃~761℃
Note: Use the front reference terminalsocket for connection.

2.5Thermal resistance temperature measurement parameters

 

Type Measuring range Accuracy Resolution Remark
Pt10 -200℃~800℃ ±0.7℃ 0.001℃ Using four-wire measurement method
Pt100(385/392),Pt1000 ±0.08℃@100℃, ±0.18℃@700℃
Pt200 ±0.25℃@100℃, ±0.45℃@700℃
Pt500 ±0.19℃@100℃, ±0.37℃@700℃
Cu50 -50℃~150℃

-50℃~150℃

±0.17℃@100℃
Cu100 ±0.11℃@100℃
External reference resistance 0℃~700℃ ±0.05℃@100℃, ±0.07℃@300℃, ±0.10℃@600℃
Note: The resistance to be calibrated is wired through the terminals on the front panel, and the external reference resistance is connected through the REFER port.

3. Matching thermostatic block

 

PR6115A/ PR6135A (Standard)

1.png

PR6115B/ PR6135B

6.png

PR6115C/ PR6135C

2.png

PR6115D/ PR6135D

7.png

PR6115E/ PR6135E

3.png

PR6115F/ PR6135F

8.png

PR6115T/ PR6135T

4.png

PR6115H/ PR6135H

9.png

PR6115K/ PR6135K

5.png

Note 1: The thermostaticblock is made of aluminum alloy.

Note 2: Other thermostatic blocks can be customized according to drawings.

4. Packaging Information

4.1 Packing list

 

No. Name description Quantity
1 PR611A/ PR613A series dry block calibratorhost 1
2 PR6115A/ PR6135Athermostatic block 1
3 High-precision external reference sensor 1
4 Special fixture for thermostatic block 1
5 Red and black test wires 4red, 2black
6 Red and black alligator clips 4red, 2black
7 220V 1A backup insurance tube 1
8 USB flash disk 1
9 Power cord 1
10 Quick Operation Guide 1
11 Instruction manual 1
12 Portable transport case 1

4.2Portable transport case

 

Item Parameter
External dimensions 47cm(H)*50cm(L)*30cm(W)
Total length of tie rod 100cm
Weight 6.0kg
0f69748941f3d8e3e4ec5ccc007042d.png8aabe18f163e04ac73046fd67804866.png

Product detail pictures:

2022 High quality Dry Block Temperature Calibrator - PR611A/ PR613A Multifunctional Dry Block Calibrator – Panran detail pictures


Related Product Guide:

To become the stage of realizing dreams of our employees! To build a happier, much more united and far more professional team! To reach a mutual profit of our clients, suppliers, the society and ourselves for 2022 High quality Dry Block Temperature Calibrator - PR611A/ PR613A Multifunctional Dry Block Calibrator – Panran , The product will supply to all over the world, such as: Moscow, Macedonia, kazan, We have now a large share in global market. Our company has strong economic strength and offers excellent sale service. Now we have established faith, friendly, harmonious business relationship with customers in different countries. , such as Indonesia, Myanmar, Indi and other Southeast Asian countries and European, African and Latin American countries.
The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
5 Stars By Bella from Bangalore - 2017.02.28 14:19
The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
5 Stars By Ivy from kazan - 2018.09.16 11:31