China wholesale Digital Differential Pressure Gauge - PR9112 Intelligent Pressure Calibrator – Panran
China wholesale Digital Differential Pressure Gauge - PR9112 Intelligent Pressure Calibrator – Panran Detail:
Technical Parameters
Model |
PR9112 Intelligent Pressure Calibrator |
|
Pressure Measurement |
Measurement Range |
(-0.1~250)Mpa |
Display accuracy |
±0.05%F.S, ±0.02%F.S |
|
Electric Current Measurement |
Range |
±30.0000mA |
Sensitivity |
0.1uA |
|
Accuracy |
±(0.01%R.D+0.003%F.S) |
|
Voltage Measurement |
Range |
±30.0000V |
Sensitivity |
0.1mV |
|
Accuracy |
±(0.01%R.D +0.003%F.S) |
|
Switching Value |
A group of Power/outage measurement |
|
Output function |
Direct-current output |
DC24V±0.5V |
Operating Environmental |
Working Temperature |
(-20~50)℃ |
Relative Temperature |
<95% |
|
Storage Temperature |
(-30~80)℃ |
|
Power Supply Configuration |
Power supply mode |
Lithium battery or power supply |
Battery Operating Time |
60 hours (24V with no load) |
|
Charging time |
About 4 hours |
|
Other indicators |
Size |
115mm×45mm×180mm |
Communication interface |
specialized three-core aviation plug |
|
Weight |
0.8KG |
Main Application:
1.Calibrate pressure (differential pressure) transmitter
2.Calibrate pressure switch
3.Verify the precision pressure gauge, General pressure gauge.
Product Feature:
1.Built-in manual operator function, The HART intelligent pressure transmitter can be calibrated.(optional)
2.Double-row liquid crystal display with backlight.
3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, switch between nine pressure units.
4.With DC24V output function.
5.With current, voltage measurement.
6.Measuring with switching volume.
7.With communication interface.(optional)
8. Storage capacity: total 30 pcs file, (50 data records of each file)
9.Big screen crystal liquid display
Software Configuration:
PR9112S software of pressure verification system is the supporting software of our digital pressure calibrator series products in our company, Data collection records can be performed, Auto generated form, Automatic error calculation, Print certificate.
1.Routine Pressure Range Selection Table
No. |
Pressure Range |
Type |
Class of accuracy |
01 |
(-100~0) kPa |
G |
0.02/0.05 |
02 |
(0~60)Pa |
G |
0.2/0.05 |
03 |
(0~250)Pa |
G |
0.2/0.05 |
04 |
(0 ~ 1) kPa |
G |
0.05/0.1 |
05 |
(0 ~ 2) kPa |
G |
0.05/0.1 |
06 |
(0 ~ 2.5) kPa |
G |
0.05/0.1 |
07 |
(0 ~ 5) kPa |
G |
0.05/0.1 |
08 |
(0 ~ 10) kPa |
G |
0.05/0.1 |
09 |
(0 ~ 16) kPa |
G |
0.05/0.1 |
10 |
(0 ~ 25) kPa |
G |
0.05/0.1 |
11 |
(0 ~ 40) kPa |
G |
0.05/0.1 |
12 |
(0 ~ 60) kPa |
G |
0.05/0.1 |
13 |
(0 ~ 100) kPa |
G |
0.05/0.1 |
14 |
(0 ~ 160) kPa |
G/L |
0.02/0.05 |
15 |
(0 ~ 250) kPa |
G/L |
0.02/0.05 |
16 |
(0 ~ 400) kPa |
G/L |
0.02/0.05 |
17 |
(0 ~ 600) kPa |
G/L |
0.02/0.05 |
18 |
(0 ~ 1) MPa |
G/L |
0.02/0.05 |
19 |
(0 ~ 1.6) MPa |
G/L |
0.02/0.05 |
20 |
(0 ~ 2.5) MPa |
G/L |
0.02/0.05 |
21 |
(0 ~ 4) MPa |
G/L |
0.02/0.05 |
22 |
(0 ~ 6) MPa |
G/L |
0.02/0.05 |
23 |
(0 ~ 10) MPa |
G/L |
0.02/0.05 |
24 |
(0 ~ 16) MPa |
G/L |
0.02/0.05 |
25 |
(0 ~ 25) MPa |
G/L |
0.02/0.05 |
26 |
(0 ~ 40) MPa |
G/L |
0.02/0.05 |
27 |
(0 ~ 60) MPa |
G/L |
0.05/0.1 |
28 |
(0 ~ 100) MPa |
G/L |
0.05/0.1 |
29 |
(0 ~ 160) MPa |
G/L |
0.05/0.1 |
30 |
(0 ~ 250) MPa |
G/L |
0.05/0.1 |
Remarks: G=GasL=Liquid
2.Composite Pressure Range Selection Table:
No. |
Pressure Range |
Type |
Class of accuracy |
01 |
±60 Pa |
G |
0.2/0.5 |
02 |
±160 Pa |
G |
0.2/0.5 |
03 |
±250 Pa |
G |
0.2/0.5 |
04 |
±500 Pa |
G |
0.2/0.5 |
05 |
±1kPa |
G |
0.05/0.1 |
06 |
±2kPa |
G |
0.05/0.1 |
07 |
±2.5 kPa |
G |
0.05/0.1 |
08 |
±5kPa |
G |
0.05/0.1 |
09 |
±10kPa |
G |
0.05/0.1 |
10 |
±16kPa |
G |
0.05/0.1 |
11 |
±25kPa |
G |
0.05/0.1 |
12 |
±40kPa |
G |
0.05/0.1 |
13 |
±60kPa |
G |
0.05/0.1 |
14 |
±100kPa |
G |
0.02/0.05 |
15 |
(-100 ~160) kPa |
G/L |
0.02/0.05 |
16 |
(-100 ~250) kPa |
G/L |
0.02/0.05 |
17 |
(-100 ~400) kPa |
G/L |
0.02/0.05 |
18 |
(-100 ~600) kPa |
G/L |
0.02/0.05 |
19 |
(-0.1~1)Mpa |
G/L |
0.02/0.05 |
20 |
(-0.1~1.6)Mpa |
G/L |
0.02/0.05 |
21 |
(-0.1~2.5)Mpa |
G/L |
0.02/0.05 |
Remarks:
1.Partial range can do absolutely pressure
2.Automatic temperature compensation range:(-20~50℃)
3.Pressure transfer medium requires non-corrosive
<!–
Packing
Product detail pictures:
Related Product Guide:
We believe in: Innovation is our soul and spirit. Quality is our life. Shopper need is our God for China wholesale Digital Differential Pressure Gauge - PR9112 Intelligent Pressure Calibrator – Panran , The product will supply to all over the world, such as: Jeddah, Botswana, Ethiopia, As a way to use the resource on the expanding info in international trade, we welcome prospects from everywhere on the web and offline. In spite on the high quality objects we offer you, effective and satisfying consultation service is supplied by our qualified after-sale service group. Item lists and in depth parameters and any other info weil be sent to you timely for the inquiries. So you should make contact with us by sending us emails or call us when you've got any questions about our organization. ou could also get our address information from our site and come to our enterprise. We get a field survey of our merchandise. We're confident that we are going to share mutual accomplishment and create solid co-operation relations with our companions within this market place. We're seeking forward for your inquiries.
By Sara from Thailand - 2017.06.22 12:49
The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
By Honorio from Guinea - 2017.04.08 14:55