Hot New Products Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Like a result of ours specialty and repair consciousness, our enterprise has won a superb popularity amid buyers everywhere in the environment for Industrial Temperature Calibrator, Low Temperature Calibration Bath, Calibrator, We are now on the lookout ahead to even larger cooperation with abroad consumers dependant on mutual added benefits. When you are interested in almost any of our products, be sure to experience cost-free to make contact with us for more facts.
Hot New Products Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran Detail:

Technical Parameters

Model

PR9112 Intelligent Pressure Calibrator

Pressure Measurement

Measurement Range

(-0.1~250)Mpa

Display accuracy

±0.05%F.S, ±0.02%F.S

Electric Current Measurement

Range

±30.0000mA

Sensitivity

0.1uA

Accuracy

±(0.01%R.D+0.003%F.S)

Voltage Measurement

Range

±30.0000V

Sensitivity

0.1mV

Accuracy

±(0.01%R.D +0.003%F.S)

Switching Value

A group of Power/outage measurement

Output function

Direct-current output

DC24V±0.5V

Operating Environmental

Working Temperature

(-20~50)℃

Relative Temperature

<95%

Storage Temperature

(-30~80)℃

Power Supply Configuration

Power supply mode

Lithium battery or power supply

Battery Operating Time

60 hours (24V with no load)

Charging time

About 4 hours

Other indicators

Size

115mm×45mm×180mm

Communication interface

specialized three-core aviation plug

Weight

0.8KG

Main Application:

1.Calibrate pressure (differential pressure) transmitter

2.Calibrate pressure switch

3.Verify the precision pressure gauge, General pressure gauge.

Product Feature:

1.Built-in manual operator function, The HART intelligent pressure transmitter can be calibrated.(optional)

2.Double-row liquid crystal display with backlight.

3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, switch between nine pressure units.

4.With DC24V output function.

5.With current, voltage measurement.

6.Measuring with switching volume.

7.With communication interface.(optional)

8. Storage capacity: total 30 pcs file, (50 data records of each file)

9.Big screen crystal liquid display

Software Configuration:

PR9112S software of pressure verification system is the supporting software of our digital pressure calibrator series products in our company, Data collection records can be performed, Auto generated form, Automatic error calculation, Print certificate.

1.Routine Pressure Range Selection Table

No.

Pressure Range

Type

Class of accuracy

01

(-100~0) kPa

G

0.02/0.05

02

(0~60)Pa

G

0.2/0.05

03

(0~250)Pa

G

0.2/0.05

04

(0 ~ 1) kPa

G

0.05/0.1

05

(0 ~ 2) kPa

G

0.05/0.1

06

(0 ~ 2.5) kPa

G

0.05/0.1

07

(0 ~ 5) kPa

G

0.05/0.1

08

(0 ~ 10) kPa

G

0.05/0.1

09

(0 ~ 16) kPa

G

0.05/0.1

10

(0 ~ 25) kPa

G

0.05/0.1

11

(0 ~ 40) kPa

G

0.05/0.1

12

(0 ~ 60) kPa

G

0.05/0.1

13

(0 ~ 100) kPa

G

0.05/0.1

14

(0 ~ 160) kPa

G/L

0.02/0.05

15

(0 ~ 250) kPa

G/L

0.02/0.05

16

(0 ~ 400) kPa

G/L

0.02/0.05

17

(0 ~ 600) kPa

G/L

0.02/0.05

18

(0 ~ 1) MPa

G/L

0.02/0.05

19

(0 ~ 1.6) MPa

G/L

0.02/0.05

20

(0 ~ 2.5) MPa

G/L

0.02/0.05

21

(0 ~ 4) MPa

G/L

0.02/0.05

22

(0 ~ 6) MPa

G/L

0.02/0.05

23

(0 ~ 10) MPa

G/L

0.02/0.05

24

(0 ~ 16) MPa

G/L

0.02/0.05

25

(0 ~ 25) MPa

G/L

0.02/0.05

26

(0 ~ 40) MPa

G/L

0.02/0.05

27

(0 ~ 60) MPa

G/L

0.05/0.1

28

(0 ~ 100) MPa

G/L

0.05/0.1

29

(0 ~ 160) MPa

G/L

0.05/0.1

30

(0 ~ 250) MPa

G/L

0.05/0.1

Remarks: G=GasL=Liquid

2.Composite Pressure Range Selection Table:

No.

Pressure Range

Type

Class of accuracy

01

±60 Pa

G

0.2/0.5

02

±160 Pa

G

0.2/0.5

03

±250 Pa

G

0.2/0.5

04

±500 Pa

G

0.2/0.5

05

±1kPa

G

0.05/0.1

06

±2kPa

G

0.05/0.1

07

±2.5 kPa

G

0.05/0.1

08

±5kPa

G

0.05/0.1

09

±10kPa

G

0.05/0.1

10

±16kPa

G

0.05/0.1

11

±25kPa

G

0.05/0.1

12

±40kPa

G

0.05/0.1

13

±60kPa

G

0.05/0.1

14

±100kPa

G

0.02/0.05

15

(-100 ~160) kPa

G/L

0.02/0.05

16

(-100 ~250) kPa

G/L

0.02/0.05

17

(-100 ~400) kPa

G/L

0.02/0.05

18

(-100 ~600) kPa

G/L

0.02/0.05

19

(-0.1~1)Mpa

G/L

0.02/0.05

20

(-0.1~1.6)Mpa

G/L

0.02/0.05

21

(-0.1~2.5)Mpa

G/L

0.02/0.05

Remarks:

1.Partial range can do absolutely pressure

2.Automatic temperature compensation range:(-20~50℃)

3.Pressure transfer medium requires non-corrosive


Product detail pictures:

Hot New Products Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran detail pictures

Hot New Products Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran detail pictures


Related Product Guide:

abide by the contract, conforms into the market requirement, joins in the market competition by its good quality also as provides a lot more comprehensive and great company for purchasers to let them turn into huge winner. The pursue from the firm, would be the clients' gratification for Hot New Products Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran , The product will supply to all over the world, such as: Bulgaria, Estonia, Toronto, Meanwhile, we're building up and consummating triangle market & strategic cooperation in order to achieve a multi-win trade supply chain to expand our market vertically and horizontally for a brighter prospects. development. Our philosophy is to create cost-effective products, promote perfect services, cooperate for long-term and mutual benefits, firm a comprehensive mode of excellent suppliers system and marketing agents, brand strategic cooperation sales system.
We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
5 Stars By Natalie from New Delhi - 2018.03.03 13:09
The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
5 Stars By Bertha from Victoria - 2018.10.01 14:14