Hot New Products Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran
Hot New Products Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran Detail:
Technical Parameters
Model |
PR9112 Intelligent Pressure Calibrator |
|
Pressure Measurement |
Measurement Range |
(-0.1~250)Mpa |
Display accuracy |
±0.05%F.S, ±0.02%F.S |
|
Electric Current Measurement |
Range |
±30.0000mA |
Sensitivity |
0.1uA |
|
Accuracy |
±(0.01%R.D+0.003%F.S) |
|
Voltage Measurement |
Range |
±30.0000V |
Sensitivity |
0.1mV |
|
Accuracy |
±(0.01%R.D +0.003%F.S) |
|
Switching Value |
A group of Power/outage measurement |
|
Output function |
Direct-current output |
DC24V±0.5V |
Operating Environmental |
Working Temperature |
(-20~50)℃ |
Relative Temperature |
<95% |
|
Storage Temperature |
(-30~80)℃ |
|
Power Supply Configuration |
Power supply mode |
Lithium battery or power supply |
Battery Operating Time |
60 hours (24V with no load) |
|
Charging time |
About 4 hours |
|
Other indicators |
Size |
115mm×45mm×180mm |
Communication interface |
specialized three-core aviation plug |
|
Weight |
0.8KG |
Main Application:
1.Calibrate pressure (differential pressure) transmitter
2.Calibrate pressure switch
3.Verify the precision pressure gauge, General pressure gauge.
Product Feature:
1.Built-in manual operator function, The HART intelligent pressure transmitter can be calibrated.(optional)
2.Double-row liquid crystal display with backlight.
3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, switch between nine pressure units.
4.With DC24V output function.
5.With current, voltage measurement.
6.Measuring with switching volume.
7.With communication interface.(optional)
8. Storage capacity: total 30 pcs file, (50 data records of each file)
9.Big screen crystal liquid display
Software Configuration:
PR9112S software of pressure verification system is the supporting software of our digital pressure calibrator series products in our company, Data collection records can be performed, Auto generated form, Automatic error calculation, Print certificate.
1.Routine Pressure Range Selection Table
No. |
Pressure Range |
Type |
Class of accuracy |
01 |
(-100~0) kPa |
G |
0.02/0.05 |
02 |
(0~60)Pa |
G |
0.2/0.05 |
03 |
(0~250)Pa |
G |
0.2/0.05 |
04 |
(0 ~ 1) kPa |
G |
0.05/0.1 |
05 |
(0 ~ 2) kPa |
G |
0.05/0.1 |
06 |
(0 ~ 2.5) kPa |
G |
0.05/0.1 |
07 |
(0 ~ 5) kPa |
G |
0.05/0.1 |
08 |
(0 ~ 10) kPa |
G |
0.05/0.1 |
09 |
(0 ~ 16) kPa |
G |
0.05/0.1 |
10 |
(0 ~ 25) kPa |
G |
0.05/0.1 |
11 |
(0 ~ 40) kPa |
G |
0.05/0.1 |
12 |
(0 ~ 60) kPa |
G |
0.05/0.1 |
13 |
(0 ~ 100) kPa |
G |
0.05/0.1 |
14 |
(0 ~ 160) kPa |
G/L |
0.02/0.05 |
15 |
(0 ~ 250) kPa |
G/L |
0.02/0.05 |
16 |
(0 ~ 400) kPa |
G/L |
0.02/0.05 |
17 |
(0 ~ 600) kPa |
G/L |
0.02/0.05 |
18 |
(0 ~ 1) MPa |
G/L |
0.02/0.05 |
19 |
(0 ~ 1.6) MPa |
G/L |
0.02/0.05 |
20 |
(0 ~ 2.5) MPa |
G/L |
0.02/0.05 |
21 |
(0 ~ 4) MPa |
G/L |
0.02/0.05 |
22 |
(0 ~ 6) MPa |
G/L |
0.02/0.05 |
23 |
(0 ~ 10) MPa |
G/L |
0.02/0.05 |
24 |
(0 ~ 16) MPa |
G/L |
0.02/0.05 |
25 |
(0 ~ 25) MPa |
G/L |
0.02/0.05 |
26 |
(0 ~ 40) MPa |
G/L |
0.02/0.05 |
27 |
(0 ~ 60) MPa |
G/L |
0.05/0.1 |
28 |
(0 ~ 100) MPa |
G/L |
0.05/0.1 |
29 |
(0 ~ 160) MPa |
G/L |
0.05/0.1 |
30 |
(0 ~ 250) MPa |
G/L |
0.05/0.1 |
Remarks: G=GasL=Liquid
2.Composite Pressure Range Selection Table:
No. |
Pressure Range |
Type |
Class of accuracy |
01 |
±60 Pa |
G |
0.2/0.5 |
02 |
±160 Pa |
G |
0.2/0.5 |
03 |
±250 Pa |
G |
0.2/0.5 |
04 |
±500 Pa |
G |
0.2/0.5 |
05 |
±1kPa |
G |
0.05/0.1 |
06 |
±2kPa |
G |
0.05/0.1 |
07 |
±2.5 kPa |
G |
0.05/0.1 |
08 |
±5kPa |
G |
0.05/0.1 |
09 |
±10kPa |
G |
0.05/0.1 |
10 |
±16kPa |
G |
0.05/0.1 |
11 |
±25kPa |
G |
0.05/0.1 |
12 |
±40kPa |
G |
0.05/0.1 |
13 |
±60kPa |
G |
0.05/0.1 |
14 |
±100kPa |
G |
0.02/0.05 |
15 |
(-100 ~160) kPa |
G/L |
0.02/0.05 |
16 |
(-100 ~250) kPa |
G/L |
0.02/0.05 |
17 |
(-100 ~400) kPa |
G/L |
0.02/0.05 |
18 |
(-100 ~600) kPa |
G/L |
0.02/0.05 |
19 |
(-0.1~1)Mpa |
G/L |
0.02/0.05 |
20 |
(-0.1~1.6)Mpa |
G/L |
0.02/0.05 |
21 |
(-0.1~2.5)Mpa |
G/L |
0.02/0.05 |
Remarks:
1.Partial range can do absolutely pressure
2.Automatic temperature compensation range:(-20~50℃)
3.Pressure transfer medium requires non-corrosive
Product detail pictures:
Related Product Guide:
abide by the contract, conforms into the market requirement, joins in the market competition by its good quality also as provides a lot more comprehensive and great company for purchasers to let them turn into huge winner. The pursue from the firm, would be the clients' gratification for Hot New Products Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran , The product will supply to all over the world, such as: Bulgaria, Estonia, Toronto, Meanwhile, we're building up and consummating triangle market & strategic cooperation in order to achieve a multi-win trade supply chain to expand our market vertically and horizontally for a brighter prospects. development. Our philosophy is to create cost-effective products, promote perfect services, cooperate for long-term and mutual benefits, firm a comprehensive mode of excellent suppliers system and marketing agents, brand strategic cooperation sales system.
By Natalie from New Delhi - 2018.03.03 13:09
The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
By Bertha from Victoria - 2018.10.01 14:14