High quality Initial,and Buyer Supreme is our guideline to offer the ideal assistance to our shoppers.At present, we are striving our best to become amongst the ideal exporters inside our industry to satisfy shoppers more want for Pneumatic Comparison Test Pump, Temperature Switch Calibration, Black-Body Cavity Calibration Baths, We warmly welcome all standpoint inquiries from home and abroad to cooperate with us, and anticipate your correspondence.
Manufacturer for Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran Detail:

Technical Parameters

Model

PR9112 Intelligent Pressure Calibrator

Pressure Measurement

Measurement Range

(-0.1~250)Mpa

Display accuracy

±0.05%F.S, ±0.02%F.S

Electric Current Measurement

Range

±30.0000mA

Sensitivity

0.1uA

Accuracy

±(0.01%R.D+0.003%F.S)

Voltage Measurement

Range

±30.0000V

Sensitivity

0.1mV

Accuracy

±(0.01%R.D +0.003%F.S)

Switching Value

A group of Power/outage measurement

Output function

Direct-current output

DC24V±0.5V

Operating Environmental

Working Temperature

(-20~50)℃

Relative Temperature

<95%

Storage Temperature

(-30~80)℃

Power Supply Configuration

Power supply mode

Lithium battery or power supply

Battery Operating Time

60 hours (24V with no load)

Charging time

About 4 hours

Other indicators

Size

115mm×45mm×180mm

Communication interface

specialized three-core aviation plug

Weight

0.8KG

Main Application:

1.Calibrate pressure (differential pressure) transmitter

2.Calibrate pressure switch

3.Verify the precision pressure gauge, General pressure gauge.

Product Feature:

1.Built-in manual operator function, The HART intelligent pressure transmitter can be calibrated.(optional)

2.Double-row liquid crystal display with backlight.

3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, switch between nine pressure units.

4.With DC24V output function.

5.With current, voltage measurement.

6.Measuring with switching volume.

7.With communication interface.(optional)

8. Storage capacity: total 30 pcs file, (50 data records of each file)

9.Big screen crystal liquid display

Software Configuration:

PR9112S software of pressure verification system is the supporting software of our digital pressure calibrator series products in our company, Data collection records can be performed, Auto generated form, Automatic error calculation, Print certificate.

1.Routine Pressure Range Selection Table

No.

Pressure Range

Type

Class of accuracy

01

(-100~0) kPa

G

0.02/0.05

02

(0~60)Pa

G

0.2/0.05

03

(0~250)Pa

G

0.2/0.05

04

(0 ~ 1) kPa

G

0.05/0.1

05

(0 ~ 2) kPa

G

0.05/0.1

06

(0 ~ 2.5) kPa

G

0.05/0.1

07

(0 ~ 5) kPa

G

0.05/0.1

08

(0 ~ 10) kPa

G

0.05/0.1

09

(0 ~ 16) kPa

G

0.05/0.1

10

(0 ~ 25) kPa

G

0.05/0.1

11

(0 ~ 40) kPa

G

0.05/0.1

12

(0 ~ 60) kPa

G

0.05/0.1

13

(0 ~ 100) kPa

G

0.05/0.1

14

(0 ~ 160) kPa

G/L

0.02/0.05

15

(0 ~ 250) kPa

G/L

0.02/0.05

16

(0 ~ 400) kPa

G/L

0.02/0.05

17

(0 ~ 600) kPa

G/L

0.02/0.05

18

(0 ~ 1) MPa

G/L

0.02/0.05

19

(0 ~ 1.6) MPa

G/L

0.02/0.05

20

(0 ~ 2.5) MPa

G/L

0.02/0.05

21

(0 ~ 4) MPa

G/L

0.02/0.05

22

(0 ~ 6) MPa

G/L

0.02/0.05

23

(0 ~ 10) MPa

G/L

0.02/0.05

24

(0 ~ 16) MPa

G/L

0.02/0.05

25

(0 ~ 25) MPa

G/L

0.02/0.05

26

(0 ~ 40) MPa

G/L

0.02/0.05

27

(0 ~ 60) MPa

G/L

0.05/0.1

28

(0 ~ 100) MPa

G/L

0.05/0.1

29

(0 ~ 160) MPa

G/L

0.05/0.1

30

(0 ~ 250) MPa

G/L

0.05/0.1

Remarks: G=GasL=Liquid

2.Composite Pressure Range Selection Table:

No.

Pressure Range

Type

Class of accuracy

01

±60 Pa

G

0.2/0.5

02

±160 Pa

G

0.2/0.5

03

±250 Pa

G

0.2/0.5

04

±500 Pa

G

0.2/0.5

05

±1kPa

G

0.05/0.1

06

±2kPa

G

0.05/0.1

07

±2.5 kPa

G

0.05/0.1

08

±5kPa

G

0.05/0.1

09

±10kPa

G

0.05/0.1

10

±16kPa

G

0.05/0.1

11

±25kPa

G

0.05/0.1

12

±40kPa

G

0.05/0.1

13

±60kPa

G

0.05/0.1

14

±100kPa

G

0.02/0.05

15

(-100 ~160) kPa

G/L

0.02/0.05

16

(-100 ~250) kPa

G/L

0.02/0.05

17

(-100 ~400) kPa

G/L

0.02/0.05

18

(-100 ~600) kPa

G/L

0.02/0.05

19

(-0.1~1)Mpa

G/L

0.02/0.05

20

(-0.1~1.6)Mpa

G/L

0.02/0.05

21

(-0.1~2.5)Mpa

G/L

0.02/0.05

Remarks:

1.Partial range can do absolutely pressure

2.Automatic temperature compensation range:(-20~50℃)

3.Pressure transfer medium requires non-corrosive

<!–

Packing


Product detail pictures:

Manufacturer for Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran detail pictures

Manufacturer for Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran detail pictures


Related Product Guide:

The customer satisfaction is our primary target. We uphold a consistent level of professionalism, quality, credibility and service for Manufacturer for Digital Pressure Meter - PR9112 Intelligent Pressure Calibrator – Panran , The product will supply to all over the world, such as: Toronto, Frankfurt, Myanmar, It using the world's leading system for reliable operation, a low failure rate, it suitable for Argentina customers choice. Our company is situated within the national civilized cities, the traffic is very convenient, unique geographical and economic conditions. We pursue a people-oriented, meticulous manufacturing, brainstorm, build brilliant business philosophy. Strict quality management, perfect service, reasonable price in Argentina is our stand on the premise of competition. If necessary, welcome to contact us by our website or phone consultation, we'll be happy to serve you.
The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
5 Stars By Catherine from French - 2017.11.11 11:41
We have been looking for a professional and responsible supplier, and now we find it.
5 Stars By Abigail from Sevilla - 2017.09.16 13:44