We have now a hugely efficient team to deal with inquiries from buyers. Our goal is 100% client gratification by our solution high-quality, rate & our team service and take pleasure in a great popularity among clients. With several factories, we will provide a wide assortment of Pneumatic High Pressure Test Pump, Precision Digital Thermometer Readouts, Pressure Module, The main goal of our company is to live a satisfactory memory to all the customers, and establish a long term business relationship with buyers and users all over the world.
New Arrival China Calibration Of Rtd Temperature Sensors - PR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath – Panran Detail:

Product video

PR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath

Overview:

Panran Measurement & Control provides a comprehensive infrared ear thermometer and infrared forehead thermometer calibration solution. The infrared ear thermometer and forehead thermometer calibration system consists of three parts:

Part1. Black-body radiation cavity, high-emissivity black-body radiation cavity is a key component required for the calibration of infrared ear thermometers and forehead thermometers. Its structure and the quality of the internal coating have a significant impact on the calibration results.

 

Part2. Temperature source–Liquid constant temperature device, used to place and immerse the black body radiation cavity, so that each surface of the radiation cavity has excellent temperature uniformity and temperature fluctuation.

 

Part3. Temperature standard, used to measure the temperature of the medium in the liquid thermostat.

 

Part1. Black-body radiation cavity

There are two types of black body radiation chambers, which are used to calibrate infrared ear thermometers and infrared forehead thermometers. The black body cavity is gold-plated on the outside and has a high-emissivity coating inside. Requirements to meet the calibration requirements of most infrared ear thermometers and infrared forehead thermometers.

 

Item HC1656012

For infrared ear thermometer calibration

HC1686045

For infrared forehead thermometer calibration

Emissivity814 μm wavelength 0.999 0.997
Diameter of the hole 10mm 60mm
Max immersion depth 150mm 300mm
Flange diameter 130mm

 

4980260929558967_2021_08_84287bb6cd3bfaeee7405b0f652d0c17.jpg微信图片_20200319135748.jpg

Part2. Temperature source–the liquid constant temperature device

The liquid constant temperature device can choose two types of products, the PR560B infrared thermometer calibration thermostat or the PR532-N10 refrigeration thermostat, both of which have excellent temperature stability and temperature uniformity. Among them, the volume of the thermostat used for the calibration of the PR560B infrared thermometer is only 1/2 of that of an ordinary thermostat, which is convenient to move, transport, or transform it into a vehicle-mounted calibration device.

Items PR560B

infrared thermometer calibration thermostatic bath

PR532-N10

Cooling bath

Remarks
Temperature range 1090℃ -10150℃ Environment temp. 5℃~35
Accuracy 36℃,≤0.07

Full range,≤0.1

0.1+0.1%RD
Work medium Distilled water antifreeze
Resolution 0.001
Temperature uniformity 0.01 Full range

From 40mm from the bottom

Temperature stability 0.005/1min 0.01/10min 20 minutes after reaching the set temperature
Power supply 220VAC50Hz2KVA
Dimension 800mm×426mm×500mmH×H×W
Weight 60KG

Note: If the customer already has a constant temperature device that can meet the calibration requirements, it can also be used directly.

 

Part3. Temperature standard

Option 1: In response to the calibration requirements of infrared thermometers, Panran introduced the PR712A standard digital thermometer, with an annual change of better than 0.01 ° C over the full range. Compared with the PR710 and PR711 precision digital thermometers of the same series, it has a better built-in reference resistance, better temperature coefficient and long-term stability. At an ambient temperature of 10 to 35 ° C, its typical temperature coefficient is only 0.5 ppm / ° C.

 

Option 2: Traditional electrical measurement equipment + standard platinum resistance. The electrical measurement equipment in this solution can be configured with PR293 series nanovolt micro-ohm thermometer or PR291 series micro-ohm thermometer. Both series of products can meet the requirements of electrical thermometers related to infrared thermometers.

Items PR712A

Standard digital thermometer

PR293 series

Nanovolt microohm thermometer

PR291 series

Microohm thermometer

Remarks
Description High-precision integrated thermometertemp. sensor is wound typePT100sensorφ5*400mm Full-featured thermocouple and platinum resistance thermometer High-precision platinum resistance thermometer
Channel No. 1 25 2
Accuracy 0.01 Electricity20ppm(RD)+2.5ppm(FS)

Temperature36℃,≤0.008

The PR291 and PR293 thermometers use standard platinum resistance measurement functions.
Resolution 0.001 0.0001
Temperature range -5℃~50 -200℃~660
Communication 2.4G无线 RS485
Battery power duration >1400h 6h PR712Apower is AAAbattery
Dimention(Body) 104×64×30mm 230×220×112mm
Weight 110g 2800g Including battery weight

Application:

The high precision cooling thermostatic bath is suitable for measuring, biochemical, petroleum, meteorology, energy, environmental protection, medicine and other departments and manufacturers of thermometers, temperature controllers, temperature sensors and other manufacturers to test and calibrate physical parameters. It can also provide constant temperature source for other experimental research work. Example 1. Second-class standard mercury thermometer, Forehead thermometers, Infrared Surface Thermometers, Ear Thermometers, beckman thermometer, industrial platinum thermal resistance, standard copper-constantan thermocouple verification, etc.

 


Product detail pictures:

New Arrival China Calibration Of Rtd Temperature Sensors - PR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath – Panran detail pictures


Related Product Guide:

We thinks what clients think, the urgency of urgency to act from the interests of a purchaser position of principle, allowing for greater top quality, decrease processing costs, price ranges are much more reasonable, won the new and aged prospects the support and affirmation for New Arrival China Calibration Of Rtd Temperature Sensors - PR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath – Panran , The product will supply to all over the world, such as: Hongkong, Malaysia, Rwanda, Selling our products causes no risks and brings high returns to your company instead. It is our consistent pursuit to create value for clients. Our company is looking for agents sincerely. What are you waiting for? Come and join us. Now or never.
The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
5 Stars By Maria from Eindhoven - 2017.08.18 11:04
Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
5 Stars By Hilary from Pakistan - 2018.09.23 18:44