PR9111 Precision Digital Pressure Gauge
Pruducts Features:
Big screen crystal liquid display
storage capacity: Total 30pcs files, 50datas record for each file
With communication interface(optional)
Technical parameters:
- Pressure unit: mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡
- Pressure measurement:
Range: (-0.1~250)Mpa (check the selection table)
Accuracy:±0.02%F.S,±0.05%F.S
General parameters:
Dimension | Φ115*45*180mm |
Communication interface | Three core professional aviation plug |
Net Weight | 0.8Kg |
Power supply | Lithium battery |
Battery Operating Time | 60 hours |
Charging Time | about 4 hours |
Working Temperature | (-20~50)℃ |
Relative Temperature | <95% |
Storage Temperature | (-30~80)℃ |
Routine Pressure Range Selection Table
No. | Pressure Range | Type | Class of accuracy |
01 | (-100~0) kPa | G | 0.02/0.05 |
02 | (0~60)Pa | G | 0.2/0.05 |
03 | (0~250)Pa | G | 0.2/0.05 |
04 | (0 ~ 1) kPa | G | 0.05/0.1 |
05 | (0 ~ 2) kPa | G | 0.05/0.1 |
06 | (0 ~ 2.5) kPa | G | 0.05/0.1 |
07 | (0 ~ 5) kPa | G | 0.05/0.1 |
08 | (0 ~ 10) kPa | G | 0.05/0.1 |
09 | (0 ~ 16) kPa | G | 0.05/0.1 |
10 | (0 ~ 25) kPa | G | 0.05/0.1 |
11 | (0 ~ 40) kPa | G | 0.05/0.1 |
12 | (0 ~ 60) kPa | G | 0.05/0.1 |
13 | (0 ~ 100) kPa | G | 0.05/0.1 |
14 | (0 ~ 160) kPa | G/L | 0.02/0.05 |
15 | (0 ~ 250) kPa | G/L | 0.02/0.05 |
16 | (0 ~ 400) kPa | G/L | 0.02/0.05 |
17 | (0 ~ 600) kPa | G/L | 0.02/0.05 |
18 | (0 ~ 1) MPa | G/L | 0.02/0.05 |
19 | (0 ~ 1.6) MPa | G/L | 0.02/0.05 |
20 | (0 ~ 2.5) MPa | G/L | 0.02/0.05 |
21 | (0 ~ 4) MPa | G/L | 0.02/0.05 |
22 | (0 ~ 6) MPa | G/L | 0.02/0.05 |
23 | (0 ~ 10) MPa | G/L | 0.02/0.05 |
24 | (0 ~ 16) MPa | G/L | 0.02/0.05 |
25 | (0 ~ 25) MPa | G/L | 0.02/0.05 |
26 | (0 ~ 40) MPa | G/L | 0.02/0.05 |
27 | (0 ~ 60) MPa | G/L | 0.05/0.1 |
28 | (0 ~ 100) MPa | G/L | 0.05/0.1 |
29 | (0 ~ 160) MPa | G/L | 0.05/0.1 |
30 | (0 ~ 250) MPa | G/L | 0.05/0.1 |
Remarks: G=GasL=Liquid
Composite Pressure Range Selection Table:
No. | Pressure Range | Type | Class of accuracy |
01 | ±60 Pa | G | 0.2/0.5 |
02 | ±160 Pa | G | 0.2/0.5 |
03 | ±250 Pa | G | 0.2/0.5 |
04 | ±500 Pa | G | 0.2/0.5 |
05 | ±1kPa | G | 0.05/0.1 |
06 | ±2kPa | G | 0.05/0.1 |
07 | ±2.5 kPa | G | 0.05/0.1 |
08 | ±5kPa | G | 0.05/0.1 |
09 | ±10kPa | G | 0.05/0.1 |
10 | ±16kPa | G | 0.05/0.1 |
11 | ±25kPa | G | 0.05/0.1 |
12 | ±40kPa | G | 0.05/0.1 |
13 | ±60kPa | G | 0.05/0.1 |
14 | ±100kPa | G | 0.02/0.05 |
15 | (-100 ~160) kPa | G/L | 0.02/0.05 |
16 | (-100 ~250) kPa | G/L | 0.02/0.05 |
17 | (-100 ~400) kPa | G/L | 0.02/0.05 |
18 | (-100 ~600) kPa | G/L | 0.02/0.05 |
19 | (-0.1~1)Mpa | G/L | 0.02/0.05 |
20 | (-0.1~1.6)Mpa | G/L | 0.02/0.05 |
21 | (-0.1~2.5)Mpa | G/L | 0.02/0.05 |
Remarks:
1.Partial range can do absolutely pressure
2.Automatic temperature compensation range:(-20~50℃)
3.Pressure transfer medium requires non-corrosive