We often persist with the theory Quality To start with, Prestige Supreme. We are fully committed to delivering our clientele with competitively priced good quality items, prompt delivery and experienced support for Industrial Temperature Calibrator, Pressure Calibration, Ams2750, We sincerely welcome domestic and overseas retailers who phone calls, letters asking, or to vegetation to negotiate, we will present you good quality goods as well as the most enthusiastic assistance,We glance forward in your check out and your cooperation.
PriceList for Glass Thermometer Calibration - PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran Detail:

PR1231/PR1232Standard Platinum-10% Rhodium/Platium Thermocouple

Part1 Overview

The first and second grade standard platinum-iridium 10-platinum thermocouples which have high accuracy good physical and chemical properties, good oxidation resistance at high temperatures, good stability and reproducibility of thermoelectromotive force. Therefore, it is used as a standard measuring instrument in (419.527~1084.62) °C , it is also used to temperature magnitude transmit and precision temperature measure in the temperature range.

Part2 Technical parameters

Parameter index

First grade platinum-iridium 10-platinum thermocouples

Second grade platinum-iridium 10-platinum thermocouples

Positive and negative

The positive is a platinum-rhodium alloy (platinum 90% rhodium 10%), the negative is pure platinum

electrode

Two electrodes diameter is 0.5-0.015mm length is no less than 1000mm

Requirements of the thermal electromotive force

Measure junction temperature is at Cu point(1084.62℃Al point(660.323℃)

Zn point(419.527℃) and reference junction temperature is 0℃

E(tCu)=10.575±0.015mV

E(tAl)=5.860+0.37 [E(tCu)-10.575]±0.005mV

E(tZn)=3.447+0.18 [E(tCu)-10.575]±0.005mV

Stability of Thermo-electromotive force

3μV

5μV

Annual change Thermo-electromotive force at Cu point(1084.62℃

≦5μV

≦10μV

Working Temperature Range

300~1100℃

Insulating sleeve

Double hole porcelain tube or corundum tube

Outer diameter(3~4)mm, hole diameter(0.8~1.0)mm, length(500~550)mm

Part3 Application Instructions

standard platinum-iridium 10-platinum thermocouples must be in accordance with the national delivery system table,National verification procedures must be implemented. First grade standard platinum-iridium 10-platinum thermocouples can be used to measure second grade,Ⅰ grade,Ⅱ grade platinum-iridium 10-platinum thermocouples and Ⅰ grade base metal thermocouples; Second grade platinum-iridium 10-platinum thermocouples can only used to measure Ⅱ grade base metal thermocouples

National verification code

National verification name

JJG75-1995

standard platinum-iridium 10-platinum thermocouples calibration specification

JJG141-2013

Working precious metal thermocouples calibration specification

JJF1637-2017

base metal thermocouple calibration specification

Part4 Maintenance and preservation

1. The standard thermocouple calibration period is 1 year, and every year the standard thermocouple must be calibrated by metrology department.

2. The necessary supervisory calibration should be performed according to the usage.

3. The work environment of the standard thermocouple should be clean to avoid contamination of the standard thermocouple.

4. The standard thermocouple should be placed in a non-polluting condition and protected from mechanical stress.

Part5 Precautions when use

1. The insulation tube cannot be used at high temperature roasting. The original insulation tube is used after strict cleaning and high temperature roasting.

2. The insulation tube ignores positive and negative, which will cause the platinum pole to be contaminated and the thermoelectric potential value to decrease.

3. Randomly the standard thermocouple insulation tube with cheap wire will contaminate the standard thermocouple, and the protective metal tube must be used for the verification of the base metal thermocouple.

4. The standard thermocouple cannot be suddenly placed in the temperature-regulating furnace, nor be taken out from the temperature-regulating furnace. The sudden-heat and cold will affect the thermoelectric performance

5.Under normal circumstances, the verification furnace for the precious metal thermocouple and the base metal thermocouple should be strictly distinguished; if it is impossible, the clean ceramic tube or corundum tube(diameter about 15mm) should be inserted to the furnace tube for protecting precious metal Thermocouples and standard thermocouples from base metal thermocouple pollution.


Product detail pictures:

PriceList for	Glass Thermometer Calibration	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures

PriceList for	Glass Thermometer Calibration	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures

PriceList for	Glass Thermometer Calibration	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures

PriceList for	Glass Thermometer Calibration	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures


Related Product Guide:

abide by the contract, conforms towards the market requirement, joins during the market competition by its good quality likewise as provides additional comprehensive and great services for customers to let them turn out to be big winner. The pursue of your enterprise, is the clients' fulfillment for PriceList for Glass Thermometer Calibration - PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran , The product will supply to all over the world, such as: Ghana, Nicaragua, Birmingham, We are confident that we are able to provide you with opportunities and will be a valuable business partner of you. We look forward to working with you soon. Learn more about the types of products that we work with or contact us now directly with your inquiries. You are welcome to contact us anytime!
This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
5 Stars By Agatha from Jordan - 2017.08.18 11:04
Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
5 Stars By Emma from New Delhi - 2017.09.29 11:19