Standard Platinum Resistance Thermometer
I. Description
The Standard Platinum Resistance Thermometer is used for compensation in standard temperature range of 13.8033k—961.8°C, and used as a standard when testing a variety of standard thermometers and high-precision thermometers. Within the above the temperature zone, it is also used directly for measuring the temperature of high-accuracy.
The Standard Platinum Resistance Thermometer measures the temperature according to the changeable regularity of the resistance temperature of the platinum.
In accordance with the regulations of ITS90, the T90 is defined by the platinum thermometer when triple point (13.8033K) of the nitrogen balance reaches to the temperature range of silver freezing point. It is indexed by using the group of required defined freezing point and reference function as well as the deviation function of the temperature interpolation.
The above temperature zoning is divided into several and decided to work normally within the sub-temperature zone by various different forms of structure of thermometers.
See the detailed thermometers in the table below:
Type |
Classification |
Suitable Temperature Zone |
Working Length (mm) |
Temperature |
WZPB-1 |
I |
0~419.527℃ |
470±10 |
Medium |
WZPB-1 |
I |
83.8058K~419.527℃ |
470±10 |
Full |
WZPB-2 |
II |
0~419.527℃ |
470±10 |
Medium |
WZPB-2 |
II |
83.8058K~419.527℃ |
470±10 |
Full |
WZPB-7 |
I |
0~660.323℃ |
510±10 |
Medium |
WZPB-7 |
I |
83.8058K~660.323℃ |
510±10 |
Full |
WZPB-8 |
II |
0~660.323℃ |
510±10 |
Medium |
WZPB-8 |
II |
83.8058K~660.323℃ |
510±10 |
Full |
Note: The Rtp of the above thermometers is 25±1.0Ω.The external diameter of quartz tubes is φ7±0.6mm.our factory also manufactures the platinum thermometer with the temperature zone of 83.8058K~660.323℃ as the working basic standard instrument.
II. Use Information
1. Before using, firstly, check the thermometer number to be consistent with the test certificate.
2. When using, according to the lug logo of the thermometer wire terminal, connect the wire correctly. The lug① of the red wire is connected to the current positive terminal; the lug③ of the yellow wire, to the current negative terminal; and the lug② of the black wire, to the potential positive terminal; the lug④ of the green wire, to the potential negative terminal.
The following is the outline of the thermometer:
3. The current should be 1MA according to the measuring of the temperature component of the thermometer.
4. For matching the electrical measurement device of the thermometer for measuring temperature, the low resistance potentiometer of grade 1 and the standard coil resistance of grade 0.1 or the measuring precise temperature bridge as well as the accessories should be used. The complete set of electrical measuring device should be guaranteed to have the sensitivity to distinguish the changing of one ten-thousandth Ohm.
5. During the process of using, preservation and transportation, try to avoid the severe mechanical vibration of the thermometer.
6. When using the first grade Standard Platinum Resistance Thermometer to test the temperature of the second grade Standard Platinum Resistance Thermometer, should follow the verification procedures approved by National Measurement Bureau.
7. The regular test of the thermometer should be done stringently according to the relevant verification procedures and regulations .
Product detail pictures:
Related Product Guide:
We have state-of-the-art equipment. Our products are exported for the USA, the UK and so on, enjoying a fantastic status among the clients for PriceList for Glass Thermometer Calibration - Standard Platinum Resistance Thermometer – Panran , The product will supply to all over the world, such as: Puerto Rico, Detroit, Argentina, We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information if you have any questions. We are glad to work for every client.
By Christine from Nairobi - 2018.07.26 16:51
The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
By Kama from Colombia - 2017.11.20 15:58