Professional China Temperature Transmitter Calibration - PR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath – Panran

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We also offer product sourcing and flight consolidation services. We've got our personal factory and sourcing office. We can easily present you with almost every style of merchandise linked to our merchandise range for Calibration Furnace Kit, Precision Digital Pressure Module, Handheld Pressure Pumps, should you have any query or wish to place an initial order please do not hesitate to contact us.
Professional China Temperature Transmitter Calibration - PR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath – Panran Detail:

Product video

PR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath

Overview:

Panran Measurement & Control provides a comprehensive infrared ear thermometer and infrared forehead thermometer calibration solution. The infrared ear thermometer and forehead thermometer calibration system consists of three parts:

Part1. Black-body radiation cavity, high-emissivity black-body radiation cavity is a key component required for the calibration of infrared ear thermometers and forehead thermometers. Its structure and the quality of the internal coating have a significant impact on the calibration results.

 

Part2. Temperature source–Liquid constant temperature device, used to place and immerse the black body radiation cavity, so that each surface of the radiation cavity has excellent temperature uniformity and temperature fluctuation.

 

Part3. Temperature standard, used to measure the temperature of the medium in the liquid thermostat.

 

Part1. Black-body radiation cavity

There are two types of black body radiation chambers, which are used to calibrate infrared ear thermometers and infrared forehead thermometers. The black body cavity is gold-plated on the outside and has a high-emissivity coating inside. Requirements to meet the calibration requirements of most infrared ear thermometers and infrared forehead thermometers.

 

Item HC1656012

For infrared ear thermometer calibration

HC1686045

For infrared forehead thermometer calibration

Emissivity814 μm wavelength 0.999 0.997
Diameter of the hole 10mm 60mm
Max immersion depth 150mm 300mm
Flange diameter 130mm

 

4980260929558967_2021_08_84287bb6cd3bfaeee7405b0f652d0c17.jpg微信图片_20200319135748.jpg

Part2. Temperature source–the liquid constant temperature device

The liquid constant temperature device can choose two types of products, the PR560B infrared thermometer calibration thermostat or the PR532-N10 refrigeration thermostat, both of which have excellent temperature stability and temperature uniformity. Among them, the volume of the thermostat used for the calibration of the PR560B infrared thermometer is only 1/2 of that of an ordinary thermostat, which is convenient to move, transport, or transform it into a vehicle-mounted calibration device.

Items PR560B

infrared thermometer calibration thermostatic bath

PR532-N10

Cooling bath

Remarks
Temperature range 1090℃ -10150℃ Environment temp. 5℃~35
Accuracy 36℃,≤0.07

Full range,≤0.1

0.1+0.1%RD
Work medium Distilled water antifreeze
Resolution 0.001
Temperature uniformity 0.01 Full range

From 40mm from the bottom

Temperature stability 0.005/1min 0.01/10min 20 minutes after reaching the set temperature
Power supply 220VAC50Hz2KVA
Dimension 800mm×426mm×500mmH×H×W
Weight 60KG

Note: If the customer already has a constant temperature device that can meet the calibration requirements, it can also be used directly.

 

Part3. Temperature standard

Option 1: In response to the calibration requirements of infrared thermometers, Panran introduced the PR712A standard digital thermometer, with an annual change of better than 0.01 ° C over the full range. Compared with the PR710 and PR711 precision digital thermometers of the same series, it has a better built-in reference resistance, better temperature coefficient and long-term stability. At an ambient temperature of 10 to 35 ° C, its typical temperature coefficient is only 0.5 ppm / ° C.

 

Option 2: Traditional electrical measurement equipment + standard platinum resistance. The electrical measurement equipment in this solution can be configured with PR293 series nanovolt micro-ohm thermometer or PR291 series micro-ohm thermometer. Both series of products can meet the requirements of electrical thermometers related to infrared thermometers.

Items PR712A

Standard digital thermometer

PR293 series

Nanovolt microohm thermometer

PR291 series

Microohm thermometer

Remarks
Description High-precision integrated thermometertemp. sensor is wound typePT100sensorφ5*400mm Full-featured thermocouple and platinum resistance thermometer High-precision platinum resistance thermometer
Channel No. 1 25 2
Accuracy 0.01 Electricity20ppm(RD)+2.5ppm(FS)

Temperature36℃,≤0.008

The PR291 and PR293 thermometers use standard platinum resistance measurement functions.
Resolution 0.001 0.0001
Temperature range -5℃~50 -200℃~660
Communication 2.4G无线 RS485
Battery power duration >1400h 6h PR712Apower is AAAbattery
Dimention(Body) 104×64×30mm 230×220×112mm
Weight 110g 2800g Including battery weight

Application:

The high precision cooling thermostatic bath is suitable for measuring, biochemical, petroleum, meteorology, energy, environmental protection, medicine and other departments and manufacturers of thermometers, temperature controllers, temperature sensors and other manufacturers to test and calibrate physical parameters. It can also provide constant temperature source for other experimental research work. Example 1. Second-class standard mercury thermometer, Forehead thermometers, Infrared Surface Thermometers, Ear Thermometers, beckman thermometer, industrial platinum thermal resistance, standard copper-constantan thermocouple verification, etc.

 


Product detail pictures:

Professional China Temperature Transmitter Calibration - PR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath – Panran detail pictures


Related Product Guide:

With sophisticated technologies and facilities, strict top quality handle, reasonable value, exceptional support and close co-operation with clients, we are devoted to furnishing the ideal worth for our clients for Professional China Temperature Transmitter Calibration - PR565 Infrared Forehead Thermometer Blackbody Radiation Calibration Bath – Panran , The product will supply to all over the world, such as: Slovak Republic, Mauritius, Serbia, We take measure at any expense to achieve essentially the most up-to-date equipment and approaches. The packing of nominated brand is our a further distinguishing feature. The products to assure years of trouble-free service has attracted a great deal customers. The solutions are obtainable in improved designs and richer assortment, they're created scientifically of purely raw supplies. It readily available in a variety of designs and specifications for your selection. The most recent kinds are a great deal better than the preceding one particular and they are quite popular with lots of prospects.
We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
5 Stars By Jeff Wolfe from Hungary - 2018.12.14 15:26
The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
5 Stars By jari dedenroth from Estonia - 2018.10.31 10:02